0.1XS5-P0.1
EXTRA SMALL SERIES +100V, 100MW
ULTRAVOLT XS SERIES
EXTRA-SMALL HIGH VOLTAGE BIASING SUPPLIES
The Ultravolt Xs Series Of Extra-small High Voltage Power Supplies Is The Smallest Regulated
DC-to-DC high voltage power supply for
Applications That Require A Bias Voltage Ranging From 0 To 100 V. Measuring Only 1.3 Cc (0.08 In3),
these modules are ideal for use in size-critical
Applications.
PRODUCT HIGHLIGHTS
Extra-small Size: 1.3 Cc Lightweight: 5 G Pcb Flat Mounting: 11 Mm Height Output From 0
To 100 V 100 Mw Output Power Low Ripple (< 50 Mv Peak To Peak) Tight Line/load
regulation < 0.01%
Low temperature coefficient < 50 ppm per C
Programmable HV output 2.0% F.S.
Output Current Limit Protection 5 Or 9 Vdc Input Metal Case For Low Radiated Noise
TYPICAL
Applications
Small, Lightweight, Portable Devices Thin-film Bias Avalanche Photo Diodes (apd) Silicon
photomultipliers (SiPM) Multi-pixel photon counters
(MPPC)
Ultrasonic Transducers Small Pzt Drivers Ate Leakage Testing Bias Supplies
2020 Advanced Energy Industries
ULTRAVOLT XS SERIES
ELECTRICAL SPECIFICATIONS
Parameter Input Voltage Vin (Pins 1 and 2) Input Current
HV Output Vout (Pin 4) Output Power Polarity HV Setting (Pin 3)
Max Output Current Iout Load Voltage Regulation Line Voltage Regulation Residual Ripple
Temperature Coefficient Output Hv Monitoring Output Reference Voltage Hv Power On/off Operating
Temperature Storage Temperature Safeguards
Shielding
Specifications 5 Vdc 0.5 (recommended) Max: 12 Vdc (reverse: -0.2 V) For 0 V Output Voltage: < 1.6
For 100 V, No Load: < 3 At Full Output Voltage, Full Load: < 50 0 To 100 Programmable 0 To 100 Fixed
Positive Or Negative Via External Voltage Source 0/2.5 V Accuracy: 2% At Full Scale 1 Nominal
0.01% Of Full Output Voltage For No Load To Full Load 0.01% Of Full Output Voltage Over Specified
Input Voltage Range < 50 Mv Pk To Pk - Ripple Can Be Reduced To < 10 Mv By Adding An External 100 Nf
Small Cms Capacitor < 50 N/a -10 To +65, Full Load, Max Eout, Case Temp. -10 To +70 Output Current
Internally Limited Soft Start Feature: Low Overshoot Ground Return Is To Metal Enclosure
Units VDC mA
VDC mW -
PPM/ C C C -
MECHANICAL SPECIFICATIONS
ULTRAVOLT XS SERIES
Drawing views: third angle projections.