0026A0664-9
Cables, Wires - Coaxial Cables (RF) - COAX CABLE-DATA BUS
CHEMINAX
SPECIFICATION CONTROL DRAWING
100 OHMS, AWG 26, 19 STRANDS OF AWG 38, TWIN CONDUCTOR CABLE, OUTER SPACE
0026A0664
Date: 12-13-06
Revision:
This Specification Sheet Forms A Part Of The Latest Issue Of Raychem Specification 1200.
CONSTRUCTION DETAILS
ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED.
CHARACTERISTIC IMPEDANCE
100 10 ohms, Method D at 1 MHz
.020 .060
CONDUCTOR AWG 26, 19 Strands of AWG 38, Silver-Coated High Strength Copper Alloy
Dielectric Radiation-crosslinked Modified Etfe (dual Extruded) Color - Light Blue/white
SHIELD AWG 38 Tin-Coated Copper
CAPACITANCE - MUTUAL
16.0 pF/ft. (nominal)
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING (Test Procedures per SAE AS22759)
CROSSLINK PROOF
LOW TEMPERATURE COLD BEND SHRINKAGE
Insulation Resistance Insulation (dielectric) (total Insulation) Tensile Strength Elongation
INSULATION FLAWS SPARK TEST IMPULSE TEST
300 3 C For 1 Hour, .750 Inch Mandrel, .625 Lb., 2.5 Kv Dielectric Test -65 2 C For 4 Hours,
.500 Inch Mandrel, .500 Lb., 2.5 Kv Dielectric Test 200 3 C For 1 Hours, .125 Inch (maximum) In
12 inches 5000 megohms for 1000 ft. (minimum)
5000 lbf/in (minimum) 50% (minimum)
3.0 kV (rms) 8.0 kV (peak)
FINISHED CABLE (Test Procedures per NEMA WC27500)