0028S1664-9
Cables, Wires - Coaxial Cables (RF) - COAX CABLE-DATA BUS
SPECIFICATION CONTROL DRAWING
0028S1664
CHEMINAX
100 OHM, AWG 28, 7 STRANDS OF AWG 36, TWINAXIAL CABLE, OUTER SPACE USE
Date Revision
12-31-08 C
This Specification Sheet Forms A Part Of The Latest Issue Of Raychem Specification 1200.
CONSTRUCTION DETAILS
ELECTRICAL CHARACTERISTICS
DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED.
.0150 .038 .025
CONDUCTORS AWG 28, 7 Strands of AWG 36, Silver-Coated High Strength Copper Alloy
Dielectrics Radiation-crosslinked, Modified Etfe (dual Extruded) Colors - Light Blue/white
FILLERS Radiation-Crosslinked, Modified ETFE
CHARACTERISTIC IMPEDANCE MUTUAL CAPACITANCE
100 6 ohms, Method D at 1 MHz 18.3 pF/ft. (nominal)
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING (Test Procedures per SAE AS22759)
CROSSLINK PROOF
INSULATION (DIELECTRIC) (Total Insulation) ELONGATION TENSILE STRENGTH
INSULATION FLAWS SPARK TEST IMPULSE TEST
INSULATION RESISTANCE LOW TEMPERATURE-COLD BEND
SHRINKAGE
300 3 C for 1 hour, .500 inch mandrel, .375 lb., 2.5 kV dielectric test
50% (minimum) 5000 lbf/in2 (minimum)
3.0 Kv (rms) 8.0 Kv (peak) 5000 Megohms For 1000 Ft. (minimum) -65 3 C For 4 Hours, .375 Inch
Mandrel, .500 Lb., 2.5 Kv Dielectric Test 200 3 C For 1 Hour, .125 Inch (maximum) In 12 Inches
.089 .105
SHIELD AWG 40, Silver-Coated Copper