0031.1631 Datasheet

Fuseholders, Circuit Protection, FUSE HLDR CART 500V 20A PNL MNT

Stock & Ordering: Octopart | Findchips
0031.1631
Fuseholders, Circuit Protection, FUSE HLDR CART 500V 20A PNL MNT
Shock-safe Fuseholder, 5 X 20 / 6.3 X 32 Mm, Slot Knob/fingergrip, Iec: 500 Vac, Ul/csa: 600 Vac/dc
500 VAC 4 W / 10 A (VDE) 600 VAC/DC 20 A (UL/CSA)
Description - Fuseholder for 500 VAC
Applications - Cap is available slotted or with fingergrip
Standards - IEC 60127-6 - UL 4248-1 - CSA 22.2 no. 4248-1
Approvals - VDE Certificate Number: 137910 - UL File Number: E39328
Technical Data Shock-safe Category Fuse-link Mounting Terminal Rated Voltage Rated Current Rated
Power Acceptance IEC
Degree of Protection Class
Admissible Ambient Air Temp. Climatic Category Material: Socket Material: Terminals Unit Weight
(Socket/Cap) Storage Conditions Product Marking
Pc2 5 X 20 Or 6.3 X 32 Mm Panel Mount, Front Side Fixing Nut Solder Or Quick-connect 6.3 X 0.8 Mm
500 Vac (vde), 600 Vac/dc (ul/csa) 10 A (vde), 20 A (ul/csa) 4 W / 10 A @ Ta 23 C
Admissible Power Acceptance At Higher Ambient Temperature See Derating Curves Ip 40 Suitable For
Appliances With Protection Class I Or Ii Acc. To Iec 61140 -40 C To 85 C 40/085/21 Acc. To
Iec 60068-1 Thermoset, Black, Ul 94v-0 Tin-plated Copper Alloy 9 G / 5.36 G 0 C To 60 C,
max. 70% r.h.
, Type, Rated voltage, Power Acc./ Current Rating, Approvals
Applications - Equipment With Three-phase Supply (400 Vac) - Industrial Electronic
Weblinks Pdf-datasheet, Html-datasheet, General Product Information, Approvals, Ce Declaration Of
Conformity, Rohs, China-rohs, E-shop, Schurter-stock-check, Distributor-stock-check, Accessories,
Detailed request for product
Soldering Methods Solderability
Resistance to Soldering Heat
Contact Resistance Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category Pollution Degree Admissible Torque On Fixing Nut Panel Thickness S
Iron 350 C / 2 Sec Acc. To Iec 60068-2-20, Test Ta, Method 2 350 C / 10 Sec Acc. To Iec
60068-2-20, Test Tb, Method 2 < 5 M At 20 Mv > 3 Kv > 4 Kv Between L/n-pe (50 Hz; 1 Min) >
4 Kv Between L-n > 6 Kv Between L/n-pe > 10 M Between L-n > 100 M Between L/n-pe (500
VDC; 1 min) I - III acc. to IEC 60664-1 2 acc. to IEC 60664-1 max 1.2 Nm
max 9 mm
Dimension
56.5 mm
max. 9 (CSA: max. 4) SW14
19 6.3x0.8 1.8 19 6.3x0.8
M16x2/2
Variant with slot knob 0031.1631 + 0031.1611/1613
M16x2/2
Variant Fingergrip 0031.1631 + 0031.1616
16.5 -0.3