0031.3751
Fuseholders, Circuit Protection, FUSE HLDR CARTRIDGE 250V 12A PCB
Shock-Safe Fuseholder, 5 x 20 mm, Slot, vertical, IP 40 / IP 54
Variant 1
Variant 2
250 VAC 2 W / 6.3 A (VDE)12 A (UL)
Description - Vertical style - IP 40 oder IP 54 from frontside
Standards - IEC 60127-6 - UL 4248-1 / UL 512 - CSA C22.2 no. 39
Approvals - Vde Certificate Number: 129370 - Ul File Number: E39328 - Csa File Number: 38456
Technical Data Shock-safe Category Fuse-link Mounting Terminal Rated Voltage Rated Current Rated
Power Acceptance IEC
Degree of Protection Class
Admissible Ambient Air Temp. Climatic Category Material: Socket Material: Cap Material: Terminals
Unit Weight (Socket/Cap) Storage Conditions Product Marking
Pc2 5 X 20 Mm Pcb Solder Tht 250 Vac 6.3 A (vde), 12 A (ul) 2 W / 6.3 A @ Ta 23 C
Admissible Power Acceptance At Higher Ambient Temperature See Derating Curves Ip 40 / Ip 54 Suitable
For Appliances With Protection Class I Or Ii Acc. To Iec 61140 -40 C To 85 C 40/085/21 Acc.
To Iec 60068-1 Thermoplastic, Black, Ul 94v-0 Thermoplastic, Black, Ul 94v-0 Tin-plated Copper Alloy
5.03 g 0 C to 60 C, max. 70% r.h.
, Type, Rated voltage, Current, Approvals
Weblinks Pdf-datasheet, Html-datasheet, General Product Information, Approvals, Ce Declaration Of
Conformity, Rohs, China-rohs, E-shop, Schurter-stock-check, Distributor-stock-check, Detailed
request for product
Soldering Methods Solderability
Resistance to Soldering Heat
Contact Resistance Dielectric Strength
Impulse Withstand Voltage Insulation Resistance
Overvoltage Category Pollution Degree
Wave 235 C / 2 Sec Acc. To Iec 60068-2-20, Test Ta, Method 1 260 C / 10 Sec Acc. To Iec
60068-2-20, Test Tb, Method 1a < 5 M At 20 Mv > 3 Kv (50 Hz; 1 Min) > 4 Kv Between L-n >
10 M Between L-n (500 Vdc; 1 Min) I - Iii Acc. To Iec 60664-1 - 3 Acc. To Iec 60664-1
Dimension
38.4 mm
12.4 -0.15
max. 12.5
Variant 1: 0031.3701 and 0031.3703
4.7 0.5
10 0.15 max. 12.5
1.05 0.05
max. 12.5