DL2000UB-10V Datasheet

CURRENT TRANSDUCER 2000A

Stock & Ordering: Octopart | Findchips
DL2000UB-10V
CURRENT TRANSDUCER 2000A
DL2000UB-10V
Ultra-stable, High Precision (ppm Class) Fluxgate Technology Ds Series Current Transducer For
non-intrusive, isolated DC and AC current measurement up to 2000A
FEATURES
20 Ppm Linearity 15 Ppm Offset 10v Output In Bnc Connector @ 2000a Fluxgate, Closed Loop Compensated
Technology With Fixed Excitation Frequency And Second Harmonic Zero Flux Detection For Best In Class
Accuracy And Stability Industry Standard Dsub 9 Pin Connection Green Diode For Normal Operation
Indication Full Aluminum Body For Superior Emi Shielding And Extended Operating Temperature Range
Aperture 68mm for large cables and bus bars
Applications:
Mps For Particles Accelerators Gradient Amplifiers For Mri Devices Stable Power Supplies Precision
Drives Batteries Testing And Evaluation Systems Power Measurement And Power Analysis Current
calibration purposes
Specification highlights
Nom Inal Prim Ary Ac Current Nom Inal Prim Ary Dc Current Measuring Range Prim Ary / Secondary Ratio
Linearity error
Symbol
IPN A C IPN DC
A rms A
V/kA ppm
-2000 -2200 5.0000
Offset current (including earth field)
DC-10Hz Overall accuracy @25 C
(= L + IOE) AC Maxim um gain error 10Hz to
Operating temperature range
Power supply voltages
All ppm (or %) values refer to nominal current
page 1 - 2019-11-05
1414 2000 2200 5.0000
0.01 65
DL2000UB-10V
Electrical Specifications At Ta=23 C, Supply Voltage = 15v Unless Otherwise Stated
Parameter Nominal Primary Ac Current Nominal Primary Dc Current Measuring Range Overload Capacity
Nominal output voltage Primary / secondary ratio
Symbol
IPN AC IPN DC
IPM OL ISN Ratio